BRY air-cooled high-temperature centrifugal pump
BRY air-cooled high-temperature centrifugal pump is an energy-saving new product designed and manufactured in accordance with GB5662. The pump has excellent performance, reasonable structure, and is suitable for use. Suitable for conveying high-temperature liquids without solid particles.
Its degree and usage temperature are divided into three categories based on the material of the main parts in contact with the medium, 1. HT200. ZG230-450. 3.1Gr18Ni9Ti. 0Gr18Ni12Mo2Ti.
BRY air-cooled high-temperature centrifugal pump is suitable for the following ranges
1. Petroleum and chemical industry: polymerization, condensation, distillation, distillation, melting, etc;
2. Oil and fat industry: distillation of fatty acids, decomposition of oils and fats, esterification, etc;
3. Synthetic fiber industry: polymerization melting, spinning, extension, etc;
4. Textile printing and dyeing industry: heat setting, drying, hot melt dyeing, etc;
5. Plastic and rubber industry: hot pressing, rolling, extrusion, vulcanization molding, etc;
6. Paper industry: drying, corrugated paper processing, etc;
7. Wood industry: plywood, fiber hot pressing, wood drying, etc;
8. Construction industry: asphalt heating, etc; In addition, it is widely used in the mechanical industry and pharmaceutical production.
Performance range of BRY air-cooled high-temperature centrifugal pump (according to design points)
1. Flow rate 1-500 meters ³/ H; 2. Lift 10-125m; 3. Temperature -20 º C-350 º C;
BRY air-cooled high-temperature centrifugal pump model representation: Taking BRY50-32-200A as an example
BRY 50-32-200 A
BRY means: hot oil pump
50 represents: pump inlet diameter (mm)
32 represents: pump outlet diameter (mm)
200 represents: nominal outer diameter of impeller (mm)
A represents: one-time cutting of impeller outer diameter
Explanation: The order of impeller diameters is represented by A, B, and C. Cutting is not indicated for larger diameters.
Technical parameters of BRY air-cooled high-temperature centrifugal pump
model | Entrance and exit caliber mm | flow | liftM | speed r/min | power | power % | Equipped with motor model | ||
m³/h | L/min | Shaft powerKw | Power allocationKw | ||||||
BRY20-20-125 | 20×20 | 1.5 | 25 | 22 | 2800 | 0.22 | 0.75 | 30 | Y80M |
BRY25-25-160 | 25×25 | 3.0 | 50 | 27 | 2840 | 0.53 | 1.5 | 30 | Y90S |
BRY32-32-160 | 32×32 | 6.0 | 100 | 28 | 2840 | 0.85 | 1.5 | 45 | Y90S |
BRY40-25-160 | 40×25 | 10 | 166 | 28 | 2840 | 1.72 | 2.2 | 50 | Y90L |
BRY50-32-160 | 50×32 | 7.5 | 125 | 34 | 2840 | 1.59 | 3.0 | 44 | Y100L |
12.5 | 208 | 30 | 2.02 | 54 | |||||
15 | 250 | 29 | 2.16 | 56 | |||||
BRY50-32-200 | 50×32 | 7.5 | 125 | 52.5 | 2900 | 2.82 | 5.5 | 38 | Y132S |
12.5 | 208 | 50 | 3.54 | 48 | |||||
18 | 300 | 40 | 3.92 | 51 | |||||
BRY50-32-200A | 50×32 | 16 | 266 | 32 | 2900 | 3.35 | 4.0 | 42 | Y112M |
BRY50-32-250 | 50×32 | 7.5 | 125 | 82 | 2900 | 5.8 | 11 | 28 | Y160M |
12.5 | 208 | 80 | 7.2 | 38 | |||||
18 | 300 | 70 | 7.8 | 51 | |||||
BRY50-32-250A | 50×32 | 16 | 266 | 60 | 2900 | 6.3 | 7.5 | 42 | Y132S |
BRY65-50-160 | 65×50 | 20 | 333 | 32 | 2900 | 3.17 | 5.5 | 55 | Y132S |
25 | 416 | 30 | 3.35 | 65 | |||||
30 | 500 | 27 | 3.71 | 66 | |||||
BRY65-40-200 | 65×40 | 15 | 250 | 48 | 2900 | 4.4 | 7.5 | 49 | Y132S |
25 | 416 | 50 | 5.7 | 60 | |||||
30 | 500 | 48 | 6.3 | 61 | |||||
BRY65-40-200A | 65×40 | 25 | 416 | 35 | 2900 | 4.0 | 5.5 | 59 | Y132S |
BRY65-40-250 | 65×40 | 15 | 250 | 82 | 2900 | 9.1 | 15 | 37 | Y160M |
25 | 416 | 80 | 10.3 | 53 | |||||
30 | 500 | 87 | 12.02 | 54 | |||||
BRY65-40-250A | 65×40 | 20 | 333 | 51 | 2900 | 5.67 | 7.5 | 49 | Y132S |
BRY65-40-315 | 65×40 | 15 | 250 | 127 | 2900 | 18.5 | 30 | 28 | Y200L |
25 | 416 | 125 | 21.3 | 40 | |||||
30 | 500 | 123 | 23 | 44 | |||||
BRY65-40-31 | 65×40 | 22.5 | 375 | 100 | 2900 | 15.3 | 22 | 40 | Y180M |
BRY80-50-200 | 80×50 | 40 | 666 | 52 | 2900 | 7.87 | 15 | 55 | Y160M |
50 | 832 | 50 | 9.8 | 70 | |||||
60 | 1000 | 46 | 10.8 | 71 | |||||
BRY80-50-200A | 80×50 | 45 | 750 | 40 | 2900 | 7.8 | 11 | 63 | Y160M |
BRY80-50-200B | 80×50 | 40 | 666 | 32 | 2900 | 6.37 | 7.5 | 55 | Y132S |
BRY80-50-250 | 80×50 | 30 | 500 | 84 | 2900 | 13.2 | 22 | 52 | Y180M |
50 | 832 | 80 | 17.3 | 63 | |||||
60 | 1000 | 72 | 19.2 | 64 | |||||
BRY80-50-250A | 80×50 | 43 | 716 | 60 | 2900 | 12.8 | 15 | 55 | Y160M |
BRY80-50-315 | 80×50 | 30 | 500 | 128 | 2900 | 25.5 | 37 | 41 | Y200L |
50 | 832 | 125 | 31.5 | 56 | |||||
60 | 1000 | 123 | 35.3 | 58 | |||||
BRY80-50-31 | 80×50 | 45 | 750 | 100 | 2900 | 23.6 | 30 | 52 | Y200L |
BRY100-65-200 | 100×65 | 60 | 1000 | 54 | 2900 | 13.6 | 22 | 65 | Y180M |
100 | 1664 | 50 | 17.9 | 76 | |||||
120 | 2000 | 47 | 19.9 | 77 | |||||
BRY100-65-200A | 100×65 | 94 | 1566 | 44 | 2900 | 16 | 22 | 70 | Y180M |
BRY100-65-200B | 100×65 | 87 | 1450 | 38 | 2900 | 13.8 | 15 | 65 | Y160M |
BRY100-65-200C | 100×65 | 80 | 1333 | 32 | 2900 | 11.8 | 15 | 59 | Y160M |
BRY100-65-250 | 100×65 | 60 | 1000 | 87 | 2900 | 23.4 | 37 | 60 | Y200L |
100 | 1664 | 80 | 30.3 | 73 | |||||
120 | 2000 | 74 | 33.3 | 74 | |||||
BRY100-65-250A | 100×65 | 95 | 1583 | 72 | 2900 | 29 | 37 | 64 | Y200L |
BRY100-65-250B | 100×65 | 90 | 1500 | 65 | 2900 | 26.2 | 30 | 61 | Y200L |
BRY100-65-250C | 100×65 | 85 | 1416 | 50 | 2900 | 20.3 | 30 | 57 | Y200L |
BRY100-65-315 | 100×65 | 60 | 1000 | 133 | 2900 | 39.6 | 75 | 55 | Y280S |
100 | 1664 | 125 | 51.6 | 66 | |||||
120 | 2000 | 118 | 57.5 | 67 | |||||
BRY100-65-31 | 100×65 | 95 | 1583 | 113 | 2900 | 45.2 | 55 | 64 | Y250M |
BRY100-65-315B | 100×65 | 90 | 1500 | 100 | 2900 | 40.5 | 55 | 55 | Y250M |
BRY100-65-315C | 100×65 | 82 | 1366 | 84 | 2900 | 34.8 | 45 | 54 | Y225M |
BRY125-100-200 | 125×100 | 120 | 2000 | 57.5 | 2900 | 39.6 | 45 | 67 | Y225M |
200 | 3328 | 50 | 51.6 | 81 | |||||
240 | 4000 | 44.5 | 57.5 | 80 | |||||
BRY125-100-200A | 125×100 | 178 | 2966 | 40 | 2900 | 26.6 | 37 | 73 | Y200L |
BRY125-100-250 | 125×100 | 160 | 2666 | 76 | 2900 | 44.2 | 55 | 75 | Y250M |
200 | 3328 | 70 | 47 | 80 | |||||
240 | 4000 | 60 | 50.3 | 78 |
Analysis of the reasons for self-priming and high/low pressure of gear pumps
The self-priming capacity and pressure of gear pumps are influenced by various factors, wit ...
2025-06-25
Selection of inlet and outlet pipelines for gear pumps and their impact on gear pumps
The selection of inlet and outlet pipelines for gear pumps directly affects the performance ...
2025-06-18
Reasons and solutions for loud noise in gear oil pumps
The reasons and solutions for the loud noise of gear oil pumps are as follows: 1、 Common ...
2025-06-13
Which type of asphalt pump should be selected for road jointing
In road jointing construction, selecting a suitable asphalt pump requires comprehensive con ...
2025-06-11